banner
Shenzhen Agricultural Bank Business Hall Air Purification Pr
Author: Li Deng environmental protection
        The original system design of the Shenzhen Agricultural Bank branch building is equipped with fresh air sterilization, deodorization and odor removal in addition to formaldehyde air purifier system equipment, Edda Air plasma air system. Therefore, the outdoor air pollutants do not enter the room with the fresh air. Ensure purification. Add Edda Air plasma air purification equipment to the air-conditioning fan coil for internal circulation purification. The concentration of gas pollutants in the test chamber is greatly reduced. The air quality has been significantly improved. Protect the health of guests and office workers and improve work efficiency.
 

















project description:
         The outer walls of the bank building are all curtain wall structures. The windows are basically closed. The floor area is large and it is a closed space. The air cannot flow and the air quality is particularly poor. Therefore, the design institute designed a new style when designing the design. Fresh air sterilization, deodorization and odor removal in addition to formaldehyde air purifier system solution, in order to solve the problem of ventilation sterilization, disinfection, deodorization, odor removal, formaldehyde removal, but all leakages only have a ventilation outside the corner of each floor. At the time of civil construction, the exhaust duct is reserved, and the fresh air duct is reserved around the elevator. Therefore, all the fresh air purification equipment must be installed according to the requirements, the air outlet is connected with the new air duct, and the air exhaust port is connected to the air exhaust. Do not confuse. Because they are used in office and public places, the following requirements are imposed on the fresh air purification system: 1. The system operation noise can not affect the normal office; 2. There are more guests in the public places, and the design of the air volume should be compounded; 3. Fresh air outlet Can not directly blow to the office staff; 4. Control must be reasonable, it is best to be placed in the ceiling and the front desk; 5. Fresh air equipment must be energy-saving and environmental protection (level 1 energy consumption); 6. After-sales maintenance and maintenance needs to be simple and fast; 7. A professional installation team is required, which not only has a good effect, but also does not affect the overall aesthetics.

Message